content top

Chronic Systemic Metal Ion Toxicity from Wear on a Revised Cobalt-chromium Trunnion

Chronic Systemic Metal Ion Toxicity from Wear on a Revised Cobalt-chromium Trunnion

Learning Point of the Article: Following total hip arthroplasty, consideration should be given to metal ion toxicity due to trunnion wear in patients with cobalt/chromium femoral components, even with relatively low ion levels. Case Report | Volume 9 | Issue 2 | JOCR March – April 2019 | Page 48-51 | Michael S Reich, Pooya Javidan, Vikram K Garg, Steven N Copp. DOI: 10.13107/jocr.2250-0685.1366 Authors: Michael S...

Read More

Yersinia enterocolitica Arthritis after Total Hip Arthroplasty – A Case Report

Yersinia enterocolitica Arthritis after Total Hip Arthroplasty – A Case Report

Learning Point of the Article: Prosthetic joint infection generally requires removal of implants, but infection of prosthetic hip joint caused by Yersinia enterocolitica can be treated by debridement and antibiotics. Case Report | Volume 8 | Issue 6 | JOCR November – December 2018 | Page 24-26 | Takahiro Maeda, Chiaki Tanaka, Takaaki Shirai. DOI: 10.13107/jocr.2250-0685.1240 Authors: Takahiro Maeda[1], Chiaki Tanaka[1],...

Read More

An Unusual Central Dislocation of a Total Hip Arthroplasty Due to Severe Wear of a Ceramic on Cross-linked Polyethylene Bearing Coupling – A Case Report

An Unusual Central Dislocation of a Total Hip Arthroplasty Due to Severe Wear of a Ceramic on Cross-linked Polyethylene Bearing Coupling – A Case Report

Learning Point of the Article: Catastrophic failure of total hip arthroplasty due to severe component wear can drive to significant soft tissue metallosis, bone resorption and in some cases can be misdiagnosed as a dislocation. Case Report | Volume 8 | Issue 6 | JOCR November – December 2018 | Page 54-57 | Efstratios Athanaselis, George Komnos, Theofilos Karachalios. DOI: 10.13107/jocr.2250-0685.1256 Authors: Efstratios...

Read More

Progressive Osteolysis with Hematoma Following Revision Total Hip Arthroplasty using Hydroxyapatite Mesh: A Case Report

Progressive Osteolysis with Hematoma Following Revision Total Hip Arthroplasty using Hydroxyapatite Mesh: A Case Report

Learning Point for the Article: It should be careful that HA debris may become cause of osteolysis with hematoma. Case Report | Volume 8 | Issue 4 | JOCR July – August 2018 | Page 25-28| Shougo Matsuda, Nobuhiro Kaku, Tomonori Tabata, Hiroshi Tsumura. DOI: 10.13107/jocr.2250-0685.1142 Authors: Shougo Matsuda[1], Nobuhiro Kaku[1], Tomonori Tabata[1], Hiroshi Tsumura[1] [1]Department of Orthopaedic Surgery, Faculty of...

Read More

A Case Report of a Radial Nerve Palsy Following Uncomplicated Total Hip Arthroplasty

A Case Report of a Radial Nerve Palsy Following Uncomplicated Total Hip Arthroplasty

Learning Point for this Article: Management and prevention of radial nerve neuropathy following total hip arthroplasty. Case Report | Volume 8 | Issue 2 | JOCR Mar – Apr 2018 | Page 107-109| Garrett Schwarzman, Logan Schwarzman, Kyle MacGillis, Samuel Chmell. DOI: 10.13107/jocr.2250-0685.1074 Authors: Garrett Schwarzman[1], Logan Schwarzman[2], Kyle MacGillis[3], Samuel Chmell[4] [1]Department of Orthopaedics, University...

Read More

Creative Common License

Editorial Contact

Dr Ashok Shyam Editorial Office - -203, Manthan Apts, Shreesh CHS, Hajuri Road, Thane West. Maharashtra, India Tel - 022-25834545 Email - editor.jocr@gmail.com

IORG Concept

iorg-logo